Forschungszentrum Karlsruhe

Werbung
Forschungszentrum Karlsruhe
in der Helmholtz-Gemeinschaft
ANKA Synchrotron: Architecture,
use of ACS, experience of operation
Wolfgang Mexner
Forschungszentrum Karlsruhe
in der Helmholtz-Gemeinschaft
Forschungszentrum Karlsruhe GmbH
Earth +
Environment
Health
Energy
Structure of
Matter
Keytechnology
Forschungszentrum Karlsruhe
in der Helmholtz-Gemeinschaft
The Machine
0
5 10 m
storage ring
2,5 GeV/200 mA
booster
500 MeV
microtron
50 MeV
Forschungszentrum Karlsruhe
in der Helmholtz-Gemeinschaft
Beamlines at ANKA
XAS
Absorption
DIFF
Diffraction
SUL-X
FluoTopo
Fluorescence,
Topography
INE
Actinide
Research
Lithography
PX ProteinCrystallography
IR InfraRedSpectroscopy
MPI-MF Surface Diffraction
WERA Soft X-ray
Analytical Device
Forschungszentrum Karlsruhe
in der Helmholtz-Gemeinschaft
The storage ring ANKA
Circumference:
110,4 m
Diameter:
ca. 35 m
Electron energy:
2,5 GeV
Electron current:
ca. 200 mA
Life time:
> 20 h
Forschungszentrum Karlsruhe
in der Helmholtz-Gemeinschaft
Storage ring components
bending magnet
focusing magnets
insertion device
beamline front end
experiment hall
Forschungszentrum Karlsruhe
in der Helmholtz-Gemeinschaft
ANKA Machine CS Datasheet
9
device server machines
 28 different device types (IDLs)
 43 device servers
 507 devices
 more than 1500 data channels
Forschungszentrum Karlsruhe
in der Helmholtz-Gemeinschaft
ANKA Machine CS
Diagram
 Java
clients on
Windows
machines
 C++ ACS Device
servers on
Windows
 LonWorks fieldbus
with drivers in C
for Neuron nodes
Forschungszentrum Karlsruhe
in der Helmholtz-Gemeinschaft
Device Server machine
 Windows
2000 machine with LonWorks
interface card.
 Each device server started with own
batch script
 local copy of dll-s and configuration
database maintained with CVS
 remote access with VNC
Forschungszentrum Karlsruhe
in der Helmholtz-Gemeinschaft
ACS device servers at ANKA
 ACS
version 1.1 ported to windows
because of LonWorks drivers
 We had to do some fixes on BACI
properties, should they go in main ACS
branch?
 Some problems:
– with large number of slow clients monitor
dispatching starts to be “slower”
– logging server is synchronous and slows
down whole system when used
Forschungszentrum Karlsruhe
in der Helmholtz-Gemeinschaft
LNS
Errors
during
Activator
Startup
Forschungszentrum Karlsruhe
in der Helmholtz-Gemeinschaft
Power Supply Clients @ ANKA
Forschungszentrum Karlsruhe
in der Helmholtz-Gemeinschaft
SQL Snapshot Client
Forschungszentrum Karlsruhe
in der Helmholtz-Gemeinschaft
SQL-Database
Forschungszentrum Karlsruhe
in der Helmholtz-Gemeinschaft
SQL Data Retrieval with Excel
Forschungszentrum Karlsruhe
in der Helmholtz-Gemeinschaft
Data Retrieval by Fill-Number
Forschungszentrum Karlsruhe
in der Helmholtz-Gemeinschaft
Missing Clients
Configurable Alarm Table with clear
graphical status display
 Client with Bitmap with „Hot Spots“ to
select power supplies etc.

Forschungszentrum Karlsruhe
in der Helmholtz-Gemeinschaft
Upgrade to newer ACS?
 Are
mentioned problems solved in new
ACS?
 What are new features, that ANKA
would benefit of?
 How much does it take to port ACS to
Windows?
Herunterladen